Iron coagulant PIX 113 canister 20 l - aqueous solution of iron (III) sulphate is the most commonly used coagulant (on the Polish market) in the process of municipal and industrial sewage treatment. It is also used to precipitate phosphorus from sewage, remove hydrogen sulphide and condition sediments. Net weight of the product approx. 31 kg
PIX 113 Coagulant – has high quality in accordance with the European standard EN 890:2012 type 2. Shelf life: 6 months. PIX 113 is used to treat municipal and industrial sewage, precipitate phosphorus from sewage, and prevent struvite crystallization. It is also used to remove gaseous hydrogen sulphide, which is responsible for unpleasant odors. Another function that PIX 113 fulfills in sewage treatment is sludge conditioning. This process consists in changing the structure of the sludge and the surface state of dispersed solid phase particles, causing an increase in particle size and a decrease in the forces that bind them to water. The use of PIX 113 Coagulant in sewage treatment is one of the chemical methods of sludge conditioning that is most effective. It is the most common coagulant on the Polish market.
Dosing should be carried out using corrosion-resistant diaphragm pumps. The product should be used undiluted.
Chemical composition:
Total iron (Fe tot) …………..….11.8 ± 0.4 %
Iron (Fe 2+)…………………….........< 0.3%
Fe 2 SO 4 ……………………….….........…..39 - 43%
Free acid (H 2 SO 4 )……………......< 0%
Density (20°C)………………………….....…..1.52 ± 0.06 g/cm3
Viscosity (20°C)…………………....…...30 ± 10 mPas
pH (20°C)……………………….....…...< 1
Crystallization temperature……….....-20°C
Hazard statements:
H302 - Harmful if swallowed
H315 - Causes skin irritation
H318 - Causes serious eye damage.
Environmental threats
H290 - The substance or mixture is corrosive to metals, cat. 1
Precautionary statements:
P264b - Wash body thoroughly after use
P270 - Do not eat, drink or smoke when using this product.
P280 - Wear protective gloves/protective clothing/eye protection/face protection
P234 - Keep only in original container
P305+P351+P338 - If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do, continue rinsing.
P310 – Immediately call a Poison Center or doctor.
P301+P312 – If swallowed: Call a Poison Center or doctor/physician if you feel unwell.
P302+P352 – If on skin: Wash with plenty of soap and water.
P332+P313 – If skin irritation occurs: Get medical advice/attention.
P390 – Absorb spill to prevent material damage
P406 – Store in a corrosion-resistant container / ... with a resistant inner liner
P501 – Dispose of contents/container to an authorized waste disposal facility.